SEN00593-00 40 Troubleshooting E-22 The back-up alarm does not sound. 1 46 D65EX, PX, WX-15E0 Symptom of failure • The back-up alarm does not sound. General information When a failure occurs on the primary side (coil side) of the back-up alarm relay, relevant failure codes [D161KA], [D161KB] are displayed, but in case of failure on the secondary side (contact side), no fail- ure code is displayed. Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 1 Defective fuse (FS2-6) When the fuse is blown, a ground fault may have probably occurred in the circuit.
2 Defective back-up alarm relay (internal disconnection) aPrepare with starting switch OFF and diagnose with starting switch ON. When the relay is replaced with another relay while the starting switch is set to OFF and the alarm sounds after the starting switch is turned on and the machine is operated in reverse, the back-up alarm relay (BKA) is defective. 3 Disconnection in wiring harness (Disconnection or defective contact of connectors) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Wiring harness between FS2-6 – BKA (female) (1) (3) Resis- tance Max. 1 z Wiring harness between BKA (female) (2) – ST2 (female) (18) Resis- tance Max.
1 z Wiring harness between BKA (female) (5) and back-up alarm positive (+) terminal Resis- tance Max. 1 z Wiring harness between back-up alarm neg- ative (–) terminal and GND03 Resis- tance Max. 1 z 4 Defective harness grounding (Contact with ground circuit) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Between wiring harness related to FS2-6 and BKA (female) (1), (3) and ground Resis- tance Min. 1 Mz Between wiring harness between BKA (female) (5) and back-up alarm positive (+) terminal and ground Resis- tance Min. 1 Mz 5 Defective back-up alarm (internal defect) When Causes 1 to 4 are not applicable, the back-up alarm is sup- posed to be defective.