Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — E-25 MALFUNCTION OF WIPERS.

40 Troubleshooting SEN00593-00 D65EX, PX, WX-15E0 65 Possible causes and the standard values when normal Cause Standard value when normal and remarks for troubleshooting 7 Disconnection or short circuit with ground in wiring harness (Disconnection in wiring or defective contact of connec- tors or contact with ground circuit) aPrepare with starting switch OFF and diagnose with starting switch still OFF. Wiring harness between CN15 (female) (4) – CN27 (female) (3) Resis- tance Max. 1 z Between ground and wiring harness between CN15 (female) (4) – CN27 (female) (3) Resis- tance Min. 1 Mz Wiring harness between CN27 (female) (6) – CN26 (female) (4) Resis- tance Max.

1 z Between ground and wiring harness between CN27 (female) (6) – CN26 (female) (4) Resis- tance Min. 1 Mz Wiring harness among fuse (6) – CN26 (female) (3) – CN24 (4) – connector just before motor (female) (4) Resis- tance Max. 1 z Between ground and wiring harness among fuse (6) – CN26 (female) (3) – CN24 (4) – connector just before motor (female) (4) Resis- tance Min. 1 Mz Wiring harness between fuse (6) – CN15 (female) (2) (3) Resis- tance Max. 1 z Between ground and wiring harness between fuse (6) – CN15 (female) (2) (3) Resis- tance Min. 1 Mz Wiring harness among connector just before motor (female) (3) – CN24(3) – CN26 (female) (5) Resis- tance Max.

1 z Between ground and wiring harness between connector just before motor (female) (3) – CN24 (3) – CN26 (female) (5) Resis- tance Min. 1 Mz Wiring harness between CN26 (female) (6) – ground Resis- tance Max. 1 z Wiring harness among connector just before motor (female) (1) – CN24 (1) – ground Resis- tance Max. 1 z