SEN00946-00 50 Disassembly and assembly Engine and cooling system, Part 2 1 Removal and installation of engine assembly 1 4. Remove cover (1). 5. Remove the air hose, tube, and bracket assembly (2). [*1] a If the MIKALOR clamp (NC) is used, do not disconnect the hose. a Make a mark (M) at the tube end of each hose to show the original position of the hose. Special tools Removal k Disconnect the cable from the negative (–) terminal of the battery. k If the coolant temperature in the radiator is high, you may be scalded. In this case, wait until the coolant temperature lowers and then drain the coolant. k Collect the air conditioner refrigerant (R134a).
k If refrigerant (R134a) gets in your eyes, you may lose your sight. Accordingly, you must be qualified for handling the refrigerant and put on protective goggles while you are collecting the refrigerant or charging the air conditioner with refrigerant. Collecting and filling work must be con- ducted by a qualified person. 1. Remove the engine hood assembly. For details, see “Removal of engine hood assem- bly”. 6. Disconnect dust indicator hose (3). 7. Disconnect air hose (4). [*2] 8. Remove band (5). [*3] 2. Loosen the radiator cap and drain the coolant. 6 Coolant: Approx. 39 l 9. Remove air cleaner assembly (6). 3. Close the fuel stop valve.
2 D65EX, PX, WX-15E0 Symbol Part number Part name Necessity Q’ty N/R Sketch X2 799-703-1200 Service tool kit t 1 799-703-1100 Vacuum pump (100 V) t 1 799-703-1111 Vacuum pump (220 V) t 1 799-703-1121 Vacuum pump (240 V) t 1 799-703-1401 Gas leak detector t 1