Komatsu D65EX-15E0, D65PX-15E0, D65WX-15E0 — REMOVAL AND INSTALLATION OF ENGINE ASSEMBLY

50 Disassembly and assembly SEN00946-00 Installation [*2] q Carry out installation in the reverse order to removal. 3 Air hose clamp: 10.5 ± 0.5 Nm {1.07 ± 0.05 kgm} q Turbocharger side [*1] [*3] 3 Air cleaner band: 9.8 – 11.8 Nm {1 – 1.2 kgm} 3 Clamp: 7 ± 1.1 Nm {0.71 ± 0.11 kgm} q Air aftercooler side [*4], [*5] a Install each hose so that it will not be twisted. a When installing the air conditioner hoses, take care that dirt, dust, water, etc. will not enter them. a When tightening each joint of the air condi- tioner hose, check that O-ring (70) is fitted to it. a Apply sufficient amount of compressor oil for R134a (DENSO: ND-OIL8, ZEXEL: ZXL100PG (equivalent to PAG46) to each O- ring.

3 Air hose clamp: 10.5 ± 0.5 Nm {1.07 ± 0.05 kgm} Reference If the MIKALOR clamp was removed, install new one carefully according to the following procedure. a Use a new MIKALOR clamp. a Set the hose to the original (marked) position. (Insertion depth of air hose: 60 mm) a Set the bridge (BR) so that its clamp bolt will be at the bottom and it will be lapped over band (BD) by at least min. 5 mm. 2 Threads of clamp bolt: Lubricating oil: THREEBOND, PAND18B a Do not use an impact wrench. q When reusing the hose a Set the clamp to its original position. 3 MIKALOR clamp: Min. 6 Nm (1.6 kgm} q When using a new hose a Tighten until band gap (BDG) is 17 – 20 mm .

3 Tightening torque for air conditioner refriger- ant piping [*6] 3 Air hose clamp: 10.5 ± 0.5 Nm {1.07 ± 0.05 kgm} [*7], [*8] 3 Radiator hose clamp: 8.8 ± 0.5 Nm {0.9 ± 0.05 kgm} [*9] 2 Mounting bolt: Adhesive (LT-2) 3 Mounting bolt: 98.1 – 122.6 Nm {10 – 12.5 kgm} D65EX, PX, WX-15E0 7 Thread size Tightening torque 16 x 1.5 11.8 – 14.7 Nm {1.2 – 1.5 kgm} 22 x 1.5 19.6 – 24.5 Nm {2.0 – 2.5 kgm} 24 x 1.5 29.4 – 34.3 Nm {3.0 – 3.5 kgm}