CLAAS LEXION 500 series (520, 570) — Module A66 - GPS pilot module (GPB)

Electric System LEXION 500 TIC Description of function: CAN bus (Controller Area Network) Data exchange between electronic components using a serial network. - Measured value table CAN bus BIF/CAB module (A10) The abbreviation BIF stands for fieldwork computer and the abbreviation CAB for CAN bridge. This module saves the essential machine data (machine number, operating hours ...) = BIF. At the same time, this module constitutes the interface between different CAN bus systems (CLAAS - Caterpillar - Daimler/Chrysler) = CAB. Data storage All yield data is saved in the yield meter module (A21) whereas all other performance data is saved in the fieldwork computer / CAN bridge module (A10).

It is therefore recommended to transmit these data prior to replacing a defective module, using the CLAAS diagnosis system CDS. 6a-4 Lex-e-06a 03/05 CAN high (U ) eff CAN low (U ) eff Diagnosis 1.9 ± 0.2 Volt 3.2 ± 0.2 Volt System OK approx. 2.5 Volt approx. 2.5 Volt Short-circuit CAN high / CAN low approx. 1.9 Volt > 3.2 Volt Short-circuit CAN high / +12 Volt approx. 2.5 Volt Short-circuit CAN high / Earth > 1.9 Volt approx. 3.2 Volt Short-circuit CAN low / +12 Volt approx. 3.2 Volt Short-circuit CAN low / Earth