Key to diagram: Coordinates A8 AUTOCONTOUR module (CAC) ........................................ 2-i-20 A10 Fieldwork computer module (BIF/CAB)............................... 2-i-20 A12 Speed monitor module (DZW)............................................. 2-i-20 B11 Threshing drum speed sensor............................................. 5-i-16 B30 Concave position sensor..................................................... 4-l-20 DO Master valve diode PCB...................................................... 4-i-20 DS Diagnosis plug (63-pin) VIA................................................. 3-i-20 K49 Road travel main relay ........................................................
4-i-20 K52 Power supply relay .............................................................. 4-i-20 U26 Fill accumulator switch *..................................................... 5-n-20 Y17 Concave narrow solenoid coil ........................................... 5-m-20 Y18 Concave wide solenoid coil............................................... 5-m-20 Y19 Threshing drum variable-speed drive slow solenoid coil .. 5-m-20 Y20 Threshing drum variable-speed drive fast solenoid coil.... 5-m-20 Note: * Important! Switch U26 (Fill accumulator) has only a function on machines with hydro-pneumatic concave overload system. Solenoid coil 3.8 A 3.2 Ω See inscription Measured value table:
Item Component Measured value Remark B30 Sensor 12 V 0.25 V – 4.75 V (Pin 1-2) (Pin 1-3) Y17 Y18 Y19 Y20 Electric System LEXION 500 TIC 08a-2 Lex-e-08a 03/05 08a Concave adjustment / Threshing drum variable-speed drive Item Component Measured value Remark B30 Sensor 12 V 0.25 V – 4.75 V (Pin 1-2) (Pin 1-3) Y17 Y18 Y19 Y20 Solenoid coil 3.8 A 3.2 Ω See inscription