CLAAS LEXION 500 series (520, 570) — Module A66 - GPS pilot module (GPB)

Key to diagram: Coordinates A34 Grain tank module ............................................................... 2-i-20 DO Master valve diode PCB...................................................... 4-i-20 DS Diagnosis plug (63-pin) VIA................................................. 3-i-20 K49 Road travel main relay ........................................................ 4-i-20 S87 Swing out grain tank unloading tube switch.......................4-g-17 S88 Swing in grain tank unloading tube switch ......................... 4-g-17 X8 Ground speed control lever connector...............................4-g-17 Y33 Swing out grain tank unloading tube solenoid coil ............

5-m-20 Y34 Swing in grain tank unloading tube solenoid coil .............. 5-m-20 Y33 Y34 Solenoid coil 3.8 A 3.2 Ω See inscription Measured value table: Item Component Measured value Remark Electric System LEXION 500 TIC 14a-2 Lex-e-14a 03/05 14a Swinging the grain tank unloading tube Item Component Measured value Remark Y33 Y34 Solenoid coil 3.8 A 3.2 Ω See inscription