CLAAS LEXION 500 series (520, 570) — 28b - AUTOPILOT – Feeler system

TIC LEXION 500 Electric System Description of function: AUTOPILOT When the road travel circuit is unlocked and the threshing mechanism is engaged, the AUTOPILOT module (A9) is supplied with power by the main switch (S10). Following the start signal from switch (S9), the solenoid coils (Y9/Y10) are energized according to the signals: - Sensors (B7/B8) and/or - Laser pilot (B50) - of the GPS steering system (via CAN bus) The control of the steering position is performed by the wheel angle sensor (B6) in the steering cylinder. For safety reasons, the autopilot function is interrupted immediately by the signal of the overrider switch (B83) when using manual steering.

If the driver seat is left, the seat contact (Z5) will interrupt the autopilot function after approx. 5 s. The centralizing switch (R3) enables the machine to drive precisely straight ahead even when driving on a slope. For a quick response of the steering in autopilot mode, the hydraulic system is equipped with a pressure accumulator. If the pressure in this pressure accumulator falls below approx. 135 bar, an oil pressure sensor (B5) actuates the master valve (Y77) via the Autopilot module (A9 - pin 25) until the pressure level reaches approx. 165 bar again.

Accumulator filling For quick response of the steering in autopilot mode, the hydraulic system is equipped with a pressure accumulator. - pressure-controlled (by B5) If the pressure in this pressure accumulator falls below approx. 135 bar, an oil pressure sensor (B5) actuates the master valve (Y77) via the Autopilot module (A9-/ 25) until the pressure reaches approx. 165 bar again. An existing oil pressure sensor (B5) is automatically identified by the AUTOPILOT module (A9). There is no need for configuration. If no oil pressure sensor (B5) exists or if it fails, the Autopilot system automatically switches over to time-controlled filling of the accumulator.

- time-controlled (without B5) The accumulator is filled cyclically. The steering cylinder path is considered in this process. After activating the Autopilot function, the AUTOPILOT module (A9) actuates the master valve (Y77) for 0.7 sec. The accumulator pressure thus corresponds to the working hydraulics system pressure. The path covered by the steering cylinder as a function of steering movements is added up in the AUTOPILOT module (A9). After a path corresponding roughly to a drop of accumulator pressure to 150 bar, the AUTOPILOT module (A9) again actuates the master valve (Y77) automatically for 0.7 sec. 03/05 Lex-e-28b 28b-3