CLAAS LEXION 500 series (520, 570) — 30a - Open / close grain tank (electric), grain tank full signal, warning beacon

TIC LEXION 500 Electric System Description of function: Grain tank extension (electric) With the grain tank extension switch (S29), one of the relays K31 or K32 is actuated to open or close the grain tank. Depending on the sense of the rotation, the grain tank extension electric motor (M9) is supplied with earth by one of the relays K31/K32 on pin 87a, whereas the other relay, K32/K31, switches the voltage on pin 87. Grain tank full indicator / Warning beacon The earth signal of the 70% microswitch (Z28) and 100% microswitch (Z27) is displayed as a corresponding message on the terminal (A30).

If the 70 % full signal is activated via warning beacon (E47a/b) through switch (S40), the warning beacon is activated via microswitch (Z28) and relay K62. 03/05 Lex-e-30a 30a-3