CLAAS LEXION 500 series (520, 570) — 30b - Open / close grain tank (hydraulic), grain tank full signal, warning beacon

TIC LEXION 500 Electric System Description of function: Grain tank extension (hydraulic) When the road travel circuit is unlocked, relays (K31) and (K32) are supplied with power at pin 87. Earth is applied at pins 85 and 87a. The double push-button switch (S29) actuates the relays K31 and K32, actuating also the respective solenoid coil (Y182/Y183). Parallel to one of the solenoid coils (Y182/Y183), the diode PCB (DO) also actuates the master valve (Y77), since a buildup of pressure in the system is necessary for this function.

Grain tank full indicator / Warning beacon The earth signal of the 70% microswitch (Z28) and 100% microswitch (Z27) is displayed as a corresponding message on the terminal (A30). If the 70 % full signal is activated via warning beacon (E47a/b) through switch (S40), the warning beacon is activated via microswitch (Z28) and relay K62. 03/05 Lex-e-30b 30b-3