CLAAS LEXION 500 series (520, 570) — Module A12 - Speed monitor (DZW)

TIC LEXION 500 Electric System 03/05 Lex-e-M M-7 Module A12 - Speed monitor (DZW) Pin Function Component Measuring Direction Circuit variable diagram no.

1 Front attachment speed + Y90 12 V Output 18 2 Earth (GND) -31 Earth Input 6 3 CAN high - - - 6 4 Chopper circuit signal (chopper operating hours) Z58 12 V Input 19 5 Feed rake conveyor speed signal B12 0.4 V - 4.6 V Input 25 6 Grain elevator speed signal B21 0.4 V - 4.6 V Input 25 7 Rotor / finger roller speed signal B24/B74 0.4 V - 4.6 V Input 25 8 Uni-spreader speed signal B27 0.4 V - 4.6 V Input 25 9 --- --- --- --- --- 10 --- --- --- --- --- 11 Concave position signal B30 0.25 - 4.75 V Input 8 12 Concave clearance + Y18 12 V Output 8 13 Concave clearance - Y17 12 V Output 8 14 Front attachment speed - Y89 12 V Output 18 15 Electronic unit F4 12 V / 1 A Input 6 16 CAN low - - - 6 17 --- --- --- --- --- 18 Returns speed signal B29 0.4 V - 4.6 V Input 25 19 Chopper speed / uni-spreader speed signal B28 0.4 V - 4.6 V Input 25 20 Power F16 12 V / 7.5 A Input 8, 18 21 --- --- --- --- --- 22 --- --- --- --- --- 23 --- --- --- --- --- 24 --- --- --- --- --- 25 Reverse front attachment S57 12 V Output 17