TIC LEXION 500 Electric System 03/05 Lex-e-M M-13 Module A25 - Sieve adjustment Pin Function Component Measuring Direction Circuit variable diagram no.
1 Open upper sieve K42/86 12 V Output 11 2 Earth (GND) 31 Earth Input 6, 11 3 CAN high - - - 6 4 --- --- --- --- --- 5 --- --- --- --- --- 6 --- --- --- --- --- 7 --- --- --- --- --- 8 Sieve adjustment reference voltage R37, R38 5 V Output 11 9 --- --- --- --- --- 10 --- --- --- --- --- 11 --- --- --- --- --- 12 Close upper sieve K41/86 12 V Output 11 13 Open lower sieve K44/86 12 V Output 11 14 Close lower sieve K43/86 12 V Output 11 15 Electronic unit F2 12 V / 3 A Input 6, 11 16 CAN low - - - 6 17 --- --- --- --- --- 18 --- --- --- --- --- 19 --- --- --- --- --- 20 Power F2 12 V / 3 A Input 11 21 --- --- --- --- --- 22 Upper sieve actual value signal R37 0.25-4.75 V Input 11 23 Lower sieve actual value signal R38 0.25-4.75 V Input 11 24 --- --- --- --- --- 25 --- --- --- --- ---