Electric System LEXION 500 TIC M-26 Lex-e-M 03/05 Module A49 – Ground drive (EFA) Pin Function Component Measuring Direction Circuit variable diagram no.
1 Sensor earth B97, B98, R39 0V (200mA) Output 43 2 Road travel (red) S52 12V Input 4, 43 3 4-Trac (All-wheel drive) ON S1 12V Input 32 4 Reel speed controller ON/OFF S123 12V Input 43 5 Brake light and diesel engine contol unit Z84, Z85 12V Input 43 6 Ground drive forward Y141 12V (PWM) Output 43 7 --- --- --- --- --- 8 Reference - PWM Y141 ~ 0V Input 43 9 Reference - PWM Y144 ~ 0V Input 43 10 --- --- --- --- --- 11 --- --- --- --- --- 12 --- --- --- --- --- 13 RS232 GND (Diagnosis EFA) X97 --- --- 43 14 Sensors reference voltage R39, B99 5V Output 43 15 Earth supply -31 Earth Input 6 16 Hydraulic motor speed 1 B99 High-Low (+) Input 43 17 Hydraulic motor speed 2 B99 High-Low (+) Input 43 18 Service brake left / right 25 bar signal Z79-2,Z80-2 12V Input 43 19 Safety start switch / Ground speed control lever neutral signal Z57 12V Input 1 20 RS232 TxD (Diagnosis EFA) X97 --- --- 43 21 RS232 RxD (Diagnosis EFA) X97 --- --- 43 22 Ground drive shut-off valve (emergency brake) 80 bar Y143, Z79-1, Z80-1 12V Output 43 23 Reference - PWM Y142 ~ 0V Input 43 24 --- --- --- --- --- 25 Reference - PWM Y143 ~ 0V Input 43 26 27 Ground drive variable displacement motor Y144 12V (PWM) Output 43 28 Supply voltage F75 12V Input 4, 6, 43 29 Earth supply -31 Earth Input 6 30 --- --- --- --- --- 31 Ground speed control lever position I R39 0.7V - 4.8V Input 43 32 Ground speed control lever position II (inverted, redundant) R39 4.8V – 0.7V Input 43 33 --- --- --- --- --- 34 --- --- --- --- --- 35 Ground drive hydraulics forward high-pressure sensor B97 0.25-4.75V Input 43 36 Ground drive hydraulics backward high-pressure sensor B98 0.25-4.75V Input 43 37 CAN high (J1939) --- --- --- 6 38 CAN low (J1939) --- --- --- 6 39 CAN GND (J1939) --- --- --- 6 40 Brake light (ground speed control lever) K66 12V Output 49 41 EHS release A37 12V Output 44 42 Supply voltage F75 12V Input 4, 6, 43