OM4210 Automatic Lubrication System - Section 42 Page 42-3 SYSTEM COMPONENTS Solenoid Valve Solenoid valve (5, Figure 42-1), when energized, allows oil to flow to the hydraulic motor. Filter Filter assembly (21, Figure 42-2) mounted on the grease reservoir filters the grease prior to refilling the reservoir from the shop supply. A bypass indicator alerts service personnel when the filter requires replacement. Vent Valve With vent valve (7, Figure 42-1) closed, the pump continues to operate until maximum grease pressure is achieved. As this occurs, the vent valve opens and allows the grease pressure to drop to zero, so the injectors can recharge for their next output cycle.
Hydraulic Motor and Pump Rotary hydraulic pump (3 & 9, Figure 42-1) is a fully hydraulically operated grease pump. An integrated pump control manifold is incorporated with the motor to control input flow and pressure. Lubrication Cycle Timer The solid state lubrication cycle timer provides a 24 VDC timed-interval signal to energize solenoid valve (3, Figure 42-3) providing oil flow to operate the grease pump motor. This timer is mounted in the Electrical Interface Cabinet. NOTE: The pump crankcase oil level must be maintained to the level of the pipe plug (17, Figure 42-2). If necessary, refill with 10W-30 motor oil.
Pump Cutoff Pressure Switch Pressure switch (18, Figure 42-2) is a normally open switch set at 17,237 kPa (2500 psi). This switch de- energizes the pump solenoid relay when the grease line pressure reaches the switch pressure setting, turning off the motor and pump. Hydraulic oil supply inlet pressure must not exceed 20,685 kPa (3000 psi). Exceeding the rated pressure may result in damage to the sys- tem components and personal injury. Grease Pressure Failure Switch Pressure switch (24, Figure 42-2) is a normally open switch set at 13,789 kPa (2000 psi). This switch monitors grease pressure in the injector bank on the rear axle housing.
If the proper pressure is not sensed within 60 seconds (switch contacts do not close) a warning lamp circuit to notify the operator a problem exists in the lube system. Grease Reservoir Reservoir (12, Figure 42-1) has an approximate capacity of 41 kg (90 lbs.) of grease. When the grease supply is replenished by filling the system at the service center, the grease is passed through the filter to remove contaminants before it flows into the reservoir. Pressure Gauge Pressure Reducing Valve A pressure gauge can be installed where pipe plug (8, Figure 42-1) is located. The pressure gauge will indicate hydraulic oil pressure to the inlet of the hydraulic motor.
Normal pressure is 2241 - 2413 kPa (325 - 350 psi). Pressure reducing valve (4, Figure 42-1), located on the manifold reduces the hydraulic supply pressure (from the truck steering circuit) to a suitable operating pressure of 2241 - 2413 kPa (325 - 350 psi) for the hydraulic motor used to drive the lubricant pump. The pressure control valve has been factory adjusted and the setting should not be disturbed. Injectors Each injector (23, Figure 42-2) delivers a controlled amount of pressurized lubricant to a designated lube point. Refer to Figure 42-2 for locations.
Flow Control Valve Flow control valve (10, Figure 42-1) mounted on the manifold, controls the amount of oil flow to the hydraulic motor. The flow control valve has been factory adjusted and the setting should not be disturbed.