Warnings And Cautions - Section 22 OM2222 Page 22-4 These plates are located above the battery discon- nect switches on the isolation box to indicate the OFF and ON positions of the switches. The master switch will disconnect the batteries from the entire electrical system. The starter switch will disconnect the power supply to the two starters. This will prevent the truck from start- ing, but will allow for diagnostic testing of the electri- cal system if the master switch is still ON. Stop the engine and turn the key switch to the OFF position.
After the engine has stopped, wait two min- utes, and if no warning lights illuminate, then turn the battery disconnect switches to the OFF position. After the key switch is turned OFF, the interface mod- ule remains on, monitoring the park brake function and the accumulator bleeddown function. If a failure in either system is detected, an alarm will sound to notify the operator of a failure in that system. If the battery disconnect switches are turned OFF without waiting two minutes, a potential failure could be masked. Always use the battery disconnect switches before:
Storing the machine for more than one month Replacing electrical system components Performing welding maintenance Handling batteries, or starting with booster cables Replacing fuses or fusible links This plate is located above the propel lockout lever on the isolation box to indicate the OFF and ON posi- tions of the lever. When this lever is placed in the OFF position, the truck’s AC electric drive system is locked out and the truck will not propel. When the lever is placed in the ON position, the truck’s AC electric drive system will function and the truck can be driven.