PACCAR Corporation — Parameter Part Numbers

Multiplexed Electrical System Service Manual 7 Voltmeter Trim Procedure Voltmeter Trim Values Worksheet Use the following steps when determining the appropriate parameter values for the Voltage Trim Multiplier and Voltage Trim Offset. Vehicle Voltage 1. Set the park brake and turn ignition key to the ON position. 2. Make sure the Voltmeter Trim Offset and Voltmeter Trim Multiplier parameters are set to the default values. Using ESA, select 'Parameters' from the main menu screen, then select 'Standard Gauges', then scroll down to view the Voltmeter Trim Offset and Voltmeter Trim Multiplier.

If the values for these parameters are not set at the default values, use ESA to reset the values as follows: a. Default Voltmeter Trim Offset = 5,000 b. Default Voltmeter Trim Multiplier = 100,000 NOTE To correctly calibrate the voltmeter, both the Voltmeter Trim Offset and Voltmeter Trim Multiplier parameters must be reset to their default values before performing this procedure. 3. Measure the voltage at the batteries. Record the value on the worksheet as “Measured Battery Voltage Engine Off”. 4. Note the displayed voltage using ESA or with the Voltmeter CVSG. Record the value on the worksheet as “Displayed Battery Voltage Engine Off”. 5. Start the Engine. 6.

Measure the voltage at the batteries (same place as in step 3). Record the value on the worksheet as “Measured Battery Voltage Engine Running”. 7. Note the displayed voltage using ESA or with the Voltmeter CVSG. Record the value on the worksheet as “Displayed Battery Voltage Engine Running”. 8. Perform the calculations on the worksheet to determine the appropriate values for the Voltage Trim Multiplier and Voltage Trim Offset. 9. Use ESA to set the parameter values to the calculated values. PM819023/KM815057 (08/14/2012) 7 - 21 Procedure Value Worksheet Entry STEP 3: Measured BATT Voltage Engine Off A STEP 6: Measured BATT Voltage Engine Running B STEP 4:

Displayed BATT Voltage Engine Off C STEP 7: Displayed BATT Voltage Engine Running D Entry Entry Result B - A = E D - C = F E + F = G C x G = H A - H = I I x 1,000 = J J + 5,000 = K G x 100,000 = L K = Voltmeter Trim Offset Value L = Voltmeter Trim Multiplier Value