PACCAR Corporation — Terminating Resistor Test Procedure

Multiplexed Electrical System Service Manual 12 In addition to the charts, there are larger scale diagrams of the CAN databus available to print and markup with multimeter values. Terminating Resistor Test Procedure To determine if an inline resistor is working, locate the resistor. The resistors are shown on the following diagrams. If the resistor is outside the box that represents a controller, then the resistor is inline. Once a resistor has been physically found, disconnect resistors from the resistor holders and test resistance (approximately 120 ohm) of each resistor across terminals as shown. PM819023/KM815057 (08/14/2012) 12 - 17