Toyota — sec00TOC.fm

2-69 Traveling/Material Handling Controller (15 ~ 32 Model (Chopper)) T = N m (kgf-cm) [ft-lbf] T = 15 ± 2 (150 ± 20) T = [10.2 ± 1.4] T = 9.8 ± 2 (100 ± 20) [7.2 ± 1.4] T = 15 ± 2 (150 ± 20) T = [10.2 ± 1.4] T = 1.5 ± 0.2 (15 ± 2) T = [1.1 ± 0.14] T = 0.7 ± 0.1 (7 ± 1) T = [0.5 ± 0.07] T = 3.4 ± 0.5 (34 ± 5) T = [2.5 ± 0.4] CN123 CN128 T = 3.4 ± 0.5 (34 ± 5) T = [2.5 ± 0.4] CN119 T = 3.4 ± 0.5 (34 ± 5) T = [2.5 ± 0.4] T = 1.5 ± 0.2 T = (15 ± 2) T = [1.1 ± 0.14] CN133 CN135 T = 0.7 ± 0.1 (7 ± 1) T = [0.5 ± 0.07] CN137 CN130 CN132 CN126 CN114 CN118 CN127 CN115 T = 3.4 ± 0.5 (34 ± 5) T = [2.5 ± 0.4] CN117 T = 3.4 ± 0.5 (34 ± 5) T = [2.5 ± 0.4] CN116 T = 2.5 ± 0.5 (25 ± 5) T = [1.8 ± 0.4] T = 9.8 ± 2 (100 ± 20) T = [7.2 ± 1.4] CN133 T = 15 ± 2 T = (150 ± 20) T = [10.2 ± 1.4] CN139 T = 15 ± 2 (150 ± 20) T = [10.2 ± 1.4] CN130 CN117 CN132 20 ~ 32 model Caution:

Be sure to install insulating sheets without fail. Failure to install the insulating sheet for the TMD or TMP will damage the TMD and TMP. Check the insulation resistance between the bracket and each P terminal after controller reassembly. Standard: 3 M Ω or more