Toyota — sec00TOC.fm

2-78 Drive Motor Input Voltage Measuring Method (35 ~ 55 Model) Procedure 1 Disconnect the battery plug. 2 Remove the side cover RH. 3 Jack up the drive wheel. 4 Connect the (-) probe of an analog voltmeter to the N1 terminal. 5 Connect the (+) probe of the voltmeter to P7 (P8, P9, P71, P81 and P91). 6 Connect the battery plug. 7 Turn the key switch to ON. Release the park- ing brake. 8 Shift the direction switch to the forward (or back) position. 9 Depress the accelerator pedal fully and record the voltmeter reading at the time. Do not depress the brake pedal. 10 Measure in the same way for P8, P9, P71, P81 and P91.

11 Compare the voltage measured between N1 and each of P7, P8, P9, P71, P81 and P91. See that the difference is as specified below. Difference between input voltages to P7, P8, P9, P71, P81 and P91 Standard: 2 V or less N1 Material handling circuit OCL value measurement In the material handling system, the relief valve in the control valve is actuated at the stroke end of each cylinder. The OCL value of the material handling circuit is set higher than the current at the relief value set pressure. Because of relief from the hydraulic circuit before the current of the material handling circuit reaches the OCL value, the OCL value cannot be measured. P7 P8 P9 P71 P81 P91