Toyota — sec00TOC.fm

3-37 I/O MONITOR1 This function displays the temperature of each electrical component and the voltage at the respective terminal. Operation Procedure 1. Display the ANALYZER MENU screen. 2. Press switch (2) once. 3. Check that the 2. I/O MONITOR1 is displayed and press switch (3) to activate the I/O MONITOR1 function. Press switch (3) each time to sequentially display I/O1-1 through I/O1-14. 4. Functions of switches on this screen are as follows: Switch (1): Unused Switch (2): Unused Switch (3): Sequentially changes the screen from I/O1-1 to I/O1-14. Note: Press switch (3) on the I/O1-14 screen to return to the ANALYZER MENU screen.

It is impossible to directly jump from I/O MONITOR1 function screen to another test screen. Return to the ANALYZER MENU screen once and then go to the desired test menu. Switch (1) Switch (2) Press switch (3) Switch (3) Switch (4) (1) I/O1-1 screen THCD:Main drive circuit temperature ( ° C) Temperature of the main traveling circuit Press switch (3) (2) I/O1-2 screen THCD2:Main drive circuit temperature 2 ( ° C) Temperature of the main traveling circuit 2 Press switch (3) (3) I/O1-3 screen THCP:Main material handling circuit temperature ( ° C) Temperature of the main material handling circuit Press switch (3)