3-42 I/O MONITOR3 This function displays the ON/OFF status of material handling and mast control switches and analog input voltages from sensors. Operation Procedure 1. Display the ANALYZER MENU screen. 2. Press switch (2) three times. 3. Check that the 4. I/O MONITOR3 is displayed and press switch (3) to activate the Input/Output MONITOR3 function and to display I/O3-1 to I/O3-8 on the display. 4. Functions of switches on this screen are as follows: Switch (1): Unused Switch (2): Unused Switch (3): Sequentially changes the screen from I/O3-1 to I/O3-8. Note: Press switch (3) on the I/O3-8 screen to return to the ANALYZER MENU screen.
It is impossible to directly jump from I/O MONITOR3 function screen to another test screen. Return to the ANALYZER MENU screen once and then go to the desired test screen. Switch (1) Switch (2) Switch (4) Switch (3) Press switch (3) (1) I/O3-1 screen LSL:Lift 1st/2nd stage switch (main input): 0 OFF 1 ON PLSL:Lift 1st stage switch (SCPU input): 0 OFF 1 ON Switch ON/OFF quality judgment by operating the lift lever Press switch (3) (2) I/O3-2 screen SWTK:Tilt knob switch 0 OFF 1 ON LST:Tilt switch 0 OFF 1 ON (15 ~ 32 model: main input, 35 ~ 55 model: SCPU input) Switch ON/OFF quality judgement by operating the tilt knob or tilt lever. (3) I/O3-3 screen LSTF:Forward tilt switch:
0 OFF 1 ON LSTR:Backward tilt switch: 0 OFF 1 ON Switch ON/OFF quality judgment by operating the tilt lever to forward or backward Press switch (3)