3-47 Switch (1) Switch (2) Switch (3) Switch (4) Press switch (3) (1) ACT-1 screen FAND:Drive circuit fan (1):Drive circuit fan ON (0):Drive circuit fan OFF The traveling system fan operation is checked visually and observing the display while forcibly outputting the ON/OFF signal. Press switch (1) and select ON: Fan rotates and the signal is set to (1). Press switch (2) and select OFF: Rotation stops and the signal is set to (0). Press switch (3) (2) ACT-2 screen FAND2:Drive circuit fan2 (1):Drive circuit fan2 ON (0):Drive circuit fan2 OFF If not provided: --- (-) The drive system fan operation is checked visually and observing the display while forcibly outputting the ON/OFF signal.
Press switch (3) (3) ACT-3 screen SSOL:Rear stabilizer swing control solenoid. (1):Signal check line ON (error occurrence) (0):Signal check line OFF (normal) You can send signals to forcibly turn the rear stabilizer swing control solenoid ON and OFF. Check the signal check line by watching indications on the display. Press switch (3) (4) ACT-4 screen DSOL:Dead-man solenoid (1):Signal check line ON (0):Signal check line OFF Set to ON to release the deadman brake. (Traveling is enabled) Press switch (3)