3-60 Display indication Diag memory Faulty portion Defect mode Phenomenon on vehicle C0-1 C0-1 Main drive circuit Main drive circuit abnormality Traveling disabled after abnormality indication Traveling drive power supply is stopped.
C0-3 C0-3 Traveling drive Power supply abnormality C0-4 C0-4 Traveling drive Circuit abnormality C1 C1 Drive current sensor Sensor abnormality Traveling disabled after abnormality indication DM C2-1 Drive motor Motor temperature overheating Limited drive output C2-2 C2-2 Drive motor Thermo-sensor abnormality C3-1 C3-1 Main drive circuit1 Thermo-sensor abnormality Limited drive output C3-2 C3-2 Main drive circuit2 Thermo-sensor abnormality Limited drive output C4-1 C4-1 Drive accelerator Accelerator potentiometer abnormality (1) (Open) Traveling disabled C4-2 C4-2 Drive accelerator Accelerator potentiometer abnormality (2) (Open) Traveling disabled C4-3 C4-3 Drive accelerator Accelerator potentiometer abnormality (3) (Shorted) Traveling disabled C4-4 C4-4 Drive accelerator Accelerator potentiometer abnormality (4) (Shorted) Indication only C7 C7 Direction switch Switch abnormality Traveling disabled after abnormality detection C8-1 C8-1 Drive motor Drive motor rpm sensor No.1 abnormality (1) (Open) Traveling disabled after abnormality detection Traveling resumed by key OFF and then ON C8-2 C8-2 Drive motor Drive motor rpm sensor No.2 abnormality (2) (Open) C8-3 C8-3 Drive motor Drive motor rpm sensor No.1 abnormality (Shorted) C8-4 C8-4 Drive motor Drive motor rpm sensor No.2 abnormality (Shorted) CB-1 CB-1 MB (main contactor) Contactor abnormality Traveling and material handling disabled.
CB-2 CB-2 MB (main contactor) Contactor fused Indication only E0-1 E0-1 Main pump circuit Main pump circuit abnormality Material handling disabled after abnormality indication Stop of lift drive power supply E0-3 E0-3 Material handling drive Power supply abnormality E0-4 E0-4 Material handling drive Circuit abnormality E1 E1 Material handling current sensor Sensor abnormality Material handling disabled after abnormality indication PM E2-1 Pump motor Motor overheating Stop of material handling operations E2-2 E2-2 Pump motor Motor thermo-sensor abnormality E3 E3 Main pump circuit Thermo-sensor abnormality Stop of material handling operations E6 E6 Lift switch Switch abnormality Stop of material handling operations