2-57 Traveling controller (35 ~ 55 model) CN137 basic conditions (battery plug connected, key switch ON, direction lever at N, and motor cable disconnected) Connector No.⇔Connector No. Conditions Standard Remarks CN137-1 CN137-9 (N2, N2) (N2, N2) Approx. 0 V CN137-2 CN137-3 (2, MD1-) (1, MD1+) Battery plug disconnected Resistance measurement Approx. 20 Ω CN137-3 CN137-2 (1, MD1+) (2, MD1-) Measurement with (-) probe in con- tact with CN137-2 Approx. 11 V CN137-4 CN137-7 (6, MP2-) (5, MP2+) Battery plug disconnected Resistance measurement Approx. 20 Ω CN137-5 CN137-1 (44, VBMB) (N2, N2) Key switch OFF Approx. 36 V Approx. 48 V Approx.
0 V CN137-6 (19, CHOPCD-) Immeasurable ⎯ CN137-7 CN137-5 (5, MP2+) (44, VBMB) Measurement with (-) probe in con- tact with CN137-5, LSL1 ON Approx. 11 V CN137-8 CN137-1 (44, VBMB) (N2, N2) Key switch OFF Approx. 36 V Approx. 48 V Approx. 0 V CN137-9 CN137-1 (N2, N2) (N2, N2) Approx. 0 V CN137-10 CN137-11 (4, MP1-) (3, MP1+) Battery plug disconnect Resistance measurement Approx. 20 Ω CN137-11 CN137-10 (3, MP1+) (4, MP1-) Measurement with (-) probe in con- tact with CN137-10 Approx. 11 V CN137-12 CN137-1 (77, THC+) (N2, N2) Approx. 5 V