Yanmar 6D170E — FUEL SOLENOID

STRUCTURE AND FUNCTION FUEL SYSTEM A contact (electricity flows when stopped) method 02F082-K Pull-in coil TTA Holding coil Pull-in coil 1. Case . Mar 2. Coil - Holding coil Before pull-in After pull-in Inner wiring 3. Return spring 4. Plunger 6134F188A FUNCTION , FUEL When stopping the engine, the solenoid is energized, the solenoid plunger is electrically attracted, and the stop lever of the injection pump stop (non-injection) position. is moved by a rod to the As a result, the fuel is cut off and the engine is brought to a-stop. Accordingly, this solenoid is used only when the engine is being stopped; it is in free condition during ordinary operations. 11-44 | | SOLENOID . * Maker:

NIPPON > Type: Sealed Rated voltage: DC24V _* DENSO *. Operating current - Pull-in coil: Holding coil: Stroke: 20A max. 5A max. 27 mm 170-1 SERIES