. MAINTENANCE MAINTENANCE PROCEDURE MAINTENANCE MAINTENANCE PROCEDURE 4 - 27 2. Check that the coolant temperature has g one down enough to make it possib le to touch the radiator c ap surface by hand, then turn radiat or cap (1) slowly until it co ntacts the stoppe r to release the pre 3. Following this, push radiator cap (1), turn it until it contacts the stopper, then r 4. Remove the co ver (2), then set the contai ner under drain valve 5. (3) to catch the coolant mixture. Open drain valv e (3) at the bottom of the r adiator and drain the coolant. After draining th water.
When th idling to raise t e coolant, close drain valve (3), and fill with city e radiator is full, start the engine and run at low he temperature to at least 90°C (194°F), then 6. 7. 8. continue to run Stop the engin After draining t For the cleanin Close drain val for approx. 10 minutes. e and open drain valve (3) to drain the water. he water, clean the radiator with detergent. g method, follow the instruction of detergent. ve (3). ). 9. Install cover (2 10. Fill with super c oolant and tap water thro ugh the water f ille r up to t he bottom of t For details of t COOLANT. se 11.
Run the engine at low idling for 5 minutes to remove the air from th e water, then r un at high idling for 5 minutes. (Leave radiator cap (1) removed when do ing this.)