. MAINTENANCE MAINTENANCE PROCEDURE CHECK AND MAINTENANCE AIR CONDITIONER Check Level of Refrigerant (gas) WARNING Inspection and Maintenance Items 4 - 37 If the refrigerant use d in the air conditioner gets into your eyes or on y our hands, it ma y cause l oss of sight or fro stbite. Do not touch the refrigerant . Never loosen any par t of the re frigerant circuit. leaking. Do not bring any flam e close to any point w here the r efrigeran t gas is leaking. If the refrigerant (g as) level is low, the cooling effect wi ll become poor.
When the e ngine is running at fu ll throttl e and th e coole r is running at high s peed, look at the s ight gla ss (1) (i nspection window) in the refr igerant hose mouthp iece to c heck the condition of the refrigerant g as (Freon 134a) flowi ng in the refriger ant circuit. (A) No bubbles in r efrigerant flow: Suita (B) Some bubbles Lack of refrigerant (C) Colorless, tran REMARK When there are bu bbles, the refrigerant gas leve l is low, so contact your Komatsu dis tributors to have re frigerant added. If the air conditioner is run with the refrigerant gas level low, it will cause pressor.
damage to the com Inspection During Off Season Even during the off -season, operate the air conditioner f or 3 to 5 minutes once a mont h to maintain the oil film at al parts of the compr essor. Check, maintena nce items Content of check, maintenance Guideline for maintenance interval Refrigerant (gas) Charge amount Twice a year (spring, autumn) Air conditioner co ndenser Clogged fins Every 500 hours Compressor Operating condition Every 4000 hours V-belt Damage, tension Every 250 hours Blower motor, fan Operating condition (does it make abnormal noise?) When required Control mechanis m Operating condition (does it function normally?
) When required Piping mounts Mounting condition, looseness at tightening or connecting portions, leakage of gas, damage When required