. MAINTENANCE MAINTENANCE PROCEDURE CHECK FOR LOOSENESS OF HIGH-PRESSURE PIPING CLAMP, HARDENING OF RUBBER CHECK FOR MISSING FUEL SPRAY PREVENTION CAP, HARDENING OF RUBBER 4 - 81 Check visually and touch by hand to check that there i s no hardening of the rubber and no loose bolts of the mounting clamps (2 places) for the high-pressurepiping be tween the supply pump and the common rail.
If there are any se, please ask your Komatsu distributor to carry out The fuel spray prevention caps (10 places) on the fuel inje ction piping and both ends of the high-pressure piping act to p revent the fuel from coming into contact with high-tem perature parts of the engine and causing a fire if the fuel should leak or spray out. Check visually and touch by ha nd to check that there are no missing caps, loose bolts or hardening of the rubber. If there are any problems, the Komatsu distributor to carry out replacement. parts must be replaced. In this case, please ask your