. ATTACHMENTS AND OPTIONS MACHINE READY FOR ATTACHMENT HYDRAULIC CIRCUIT Adjusting Oil Flow Depending on the attachment, it is necessary to change the oil flow in the service circuit. For details of setting the oil flow, see "ATTACHMENT OPERATIONS (PAGE 6-17)". Switching Between Breaker and General Attachment When optional attachment is installed and working mode is set to B mode (1) Forms breaker circuit (one-way circuit). (2) Hydraulic oil flowing through breaker circuit passes through additional filter for breaker. (3) Relief valve is set to low pressure. When shipped from factory: 20.6 MPa (210 kg/cm 2 , 2980 PSI) (4) Maximum oil flow can be adjusted in user mode.
When optional attachment is installed and working mode is set to ATT mode (1) Forms crusher circuit (double-acting circuit). (2) Hydraulic oil flowing through crusher circuit does not pass through additional filter for breaker. (3) Relief valve is set to high pressure. When shipped from factory: 24.5 MPa (250 kg/cm 2 , 3550 PSI) (4) Maximum oil flow can be adjusted in user mode. 6 - 8 NOTICE turn circuit when a breaker is installed must return directly to the return filter, so do not use it except in B mode. The re turn c ircuit w hen a br eaker is installe d must r eturn directly to the return filte r, so do not use it except in B mode.
The st andar d set pr essure fo r the safety val ve in the service valve is set when the machine is shipp ed from the factory. When B mod e is s elected , it is set to 24.5MPa (250 kg/cm2, 3,550 PSI); when ATT mode is selected, it is se t to 20.6MP a (210 kg/cm 2, 2,982 PSI). Dependi ng on the attachment, ad justmen t may be necessary . In such a case, please ask your Komatsu distributor to car ry out the adj ustment. Switching Hydraulic Circuit Dependin g on th e type of attachment, set the working mode on the monit or as The s et pressure of the sa fety valve in th e servi ce valve and the hydraulic ci rcuit switch is a ccording t o the working mode selected.
Attachment Working mode Hydraulic circuit Set pressure of safety valve in service valve One-way circuit attachmen such as breaker t, B mode Automatically forms circuit where return circuit does not pass through control valve When shipped from factory 20.6 MPa (210 kg/cm2, 2982 PSI) Double-acting circuit attachment, such as crush ATT mode er Automatically forms circuit where return circuit passes through control valve When shipped from factory 24.5 MPa (250 kg/cm2, 3550 PSI)