170 Assembly process No. Replacement of return filter (Replacement of special flushing parts →standardfilter) (1/2) M-8 1. After the flushing is finished for work equipment circuit, replace the exclusive flushing parts with stored original element (3), strainer (4) and valve (5). a When replacing the elements, take out the element slowly so that refuses adhered to the element do not fall inside. Also, take out refuses by hand from the case. a When atmospheric temperature is at -15°C or lower, pay attention that the valve and the strainer are not re- placed with the plate. a Keep accordance with the procedure in “2.
Installing condition of element” as the element capacity will be low- er if the installing condition is wrong. No. Part Name Part No. Q'ty 3 Element 208-60-71123 1 4 Strainer 07069-25400 1 Standard element 5 Valve 208-60-71160 1 a Scrap the used flushing element. Keep accordance with the local laws for scraping. a Replaced plate is reusable, so it is recommended to store it for the next flushing work. No. Part Name Part No. Q'ty 3 Element 208-60-71123 1 4 Strainer 07069-25400 1 5 Valve 208-60-71160 1