Kaiyi D375A-6 — APPENDIX 2. Precautions for initialization procedures for VHMS controller

9) To change setting in [SHORT TREND ANALYSIS], follow the procedures below: 1] Select [SHORT TREND ANALYSIS] on the screen and press [Edit] button on the left lower part of the [File Transfer Setting] block to display the setting screen. 2] Change the setting and then press the [OK] button. a At initialization, input [20h] to [SMR] and set the function to [ON]. 11) After checking/changing all the data in [Communication Setting], press [Apply] button to settle the setting. a If the [Apply] button is pressed, the screen for checking the setting appears. Check the setting again and press the [OK] button if the setting is correct.

10) To change the setting of [Satellite Setting], follow the procedure below. 1] Press the [Edit] button in the [Satellite Setting] block to display the setting screen. 2] Set the GCC Code to the applicable area and then press the [OK] button. 12) After checking/changing the data of [Machine Information] and [Communica- tion Setting], press the [Exit] button at the right lower part of the screen to finish [VHMS Initialization Tool]. 191 GCC codes and applicable areas Code Applicable Area Code Applicable Area 1 U.S.A. 122 Korea 120 Italy 1 Brazil 120 Malaysia 130 Japan