MAINTENANCE 4. Install the filter by threading (do not spin) it onto the filter base (3) until the seal contacts the base, turn the filter by hand an additional 1/4 to 1/2 turn. Remark Do not over tighten the filter or use any tools for installation because this can damage the gasket and filter. Mechanical over tightening may distort the filter header threads or dam- age the element seal. 5. Check the level in the hydraulic system. 3 CLEAN HYDRAULIC RESERVOIR RELIEF VALVE Pressurized Reservoir. Always loosen the locking cap slowly in case there is still some pressure in the system. Fire hazard - do not use kerosene, diesel fuel or flammable liquids to clean parts.
A spark or a flame could cause a fire or an explosion. Use a nonflammable commercial solvent. 1. Park the machine on level ground, lower the blade to the ground and stop the engine as outlined above. Turn the electrical master switch to OFF. Tag all controls to prevent inadvertent starting. With the engine stopped, operate the equipment lever several times to re- lieve any pressure. Remove all outside dirt from breather (1). 2. Slowly loosen the locking reservoir cap (2) in order to relieve any pressure in the reservoir, then retighten. 3. Remove the lock ring (1) and cover (2). Remove the element (3) and clean in a nonflammable commercial solvent. Dry thoroughly.
Check o-ring (4) for wear or deterioration. Replace if necessary. Replace filter (3) and cover (2). Secure with lock ring (1). 3-58 D87E-2 D87P-2