MAINTENANCE The upper working lights (cab or canopy mounted) and the lower work- ing lights (hood and fuel tank mounted) are each protected by an auto- matic reset circuit breaker. A 15 amp circuit breaker is mounted on the underside of the instrument panel. In the event of a short circuit or ground, the circuit breaker will open and close until the trouble clears or is corrected. The circuit breaker will then return to and stay in its normal closed position. It is important to use the same capacity circuit breaker for replacement. The key switch and horn circuits are protected by an automatic reset cir- cuit breaker.
A 15 amp circuit breaker is mounted on the underside of the instrument panel. In the event of a short circuit or ground, the circuit breaker will open and close until the trouble clears or is corrected. The circuit breaker will then return to and stay in its normal closed position. It is important to use the same capacity circuit breaker for replacement. The engine coolant level circuit is protected by an automatic reset cir- cuit breaker. A 6 amp circuit breaker is mounted on the underside of the instrument panel. In the event of a short circuit or ground, the circuit breaker will open and close until the trouble clears or is corrected.
The circuit breaker will then return to and stay in its normal closed position. It is important to use the same capacity circuit breaker for replacement. The cab wiper circuit (each 10 amp, qty. 4) and blower circuit (25 amp) are each protected by an automatic reset circuit breaker. They are mounted on the back side of the cab panel. In the event of a short circuit or ground, the circuit breaker will open and close until the trouble clears or is corrected. The circuit breaker will then return to and stay in its nor- mal closed position. It is important to use the same capacity circuit breaker for replacement.
3 Batteries The following precautions must be taken when working around batter- ies: Use a battery carrier to avoid spilling electrolyte on clothing. Wearing rubber aprons and gloves is advisable. Be careful that tools or other metallic objects do not fall across the battery terminals. Never break a live circuit at the terminals. This could cause sparks. Make sure charger cable clamps or booster leads are clean and mak- ing good contact. If it becomes necessary to prepare electrolyte of a desired specific gravity, always pour the acid into the water. Always turn the charger to the off position before connecting or removing charger leads to the battery.
When charging a battery, it is recommended that the vent caps be left on. A damp cloth should be placed on top of the vent caps. D87E-2 D87P-2 3-79