Work hydraulics Hydraulic components Volumetric flow rates of work hydraulics The fixed displacement hydraulic pumps of circuits I and II are driven by the engine via a poly V-belt. As a result, both pumps pump oil as soon as the engine is running. If the hyd- raulic circuits are switched off, the flow from each respective pump is pumped back into the tank via a high-pressure filter, a bypass line and a return filter. Circuit I When connecting implements to circuit I, remember that it is not permissible to connect implements simultaneously to the same cell (color) at the front and rear.
Dual action cylinders may only be connected to one cell (co- lor) respectively and must be connected so that the actuation movement corresponds to the movements of the implement (raise: pull hydraulic control lever; lower: push hydraulic con- trol lever). The following recommendations apply to the connection of consumers: • Do not connect with the engine running • Activate the float position of the respective cell on circuit I The designation "cell" is synonymous with a hydraulic valve. Two connections are available per cell. The connections of one cell always have the same color e.g. connections 3 and 4 are supplied by cell 2 and are marked by green covers.
The flow rates of circuit I and circuit II can be switched over using the hydraulic operating unit in the cab (known as "vo- lume switchover"). This means that an implement connected to circuit II receives the flow from circuit II and vice versa. Circuit II Before switching on circuit II, a consumer (or a short circuit hose) must always be connected to the connections of circuit II in order to prevent damage to the pump. It is also possible to combine the flow rates of circuits I and II (known as "flow summation). This means that the flow rate of the other circuit is additionally made available to a consumer.
43 Introduction of the New Unimog Generation | Model Series 405 – This printout will not be recorded by the update service. Status: 03 / 2013 –