mercedes-benz Unimog Model Series 405 — UGE_Euro6_en.pdf

Power hydraulics Hydraulic components The power hydraulics are located in the platform intermedi- ate frame and can be removed if necessary (e.g. for winter service operations). They are powered by a propeller shaft on the engine power take-off (code N05). The hydraulic coup- lings are located at the vehicle rear above the end crossmem- ber. Front hydraulic connections are also optionally available, either for one circuit or for both circuits. Volumetric flow rates of power hydraulics A constant delivery rate is often necessary to operate a per- manent consumer.

As a result, both circuits of the power hydraulics (circuits III and IV) of the Unimog are equipped with variable displace- ment pumps. Before usage, the operator sets the required volumetric flow rate of the corresponding circuit on the Inst- rument using the steering wheel buttons. The volumetric flow rate in each circuit can be set steplessly to between 0 and the maximum flow rate of 90 l (up to 125 l/min in isolated cases). This is regulated irrespective of the engine speed within the capabilities of the system. If the engine speed changes during operation, the flow rate of the variable dis- placement pump remains constant (within the boundaries of the available volumetric flow rate).

Overview of circuit III (code HL4) • Rear pressure line, return line and leak oil line (code HL4) • Rear pressure line, return line and leak oil line. Plus front connections: Pressure line, return line and leak oil line (code HL4 + H93) Overview of circuit III and circuit IV (code HL5) • Rear return line and leak oil line and pressure line for each circuit respectively (code HL5) • Rear return line and leak oil line and pressure line for each circuit respectively. Lines towards front, pressure line, return line and leak oil line (code HL5 + H93). • Rear return line and leak oil line and pressure line for each circuit respectively. Front:

Return line, leak oil line and the two pressure lines for circuit III and circuit IV (code HL5 +H93 + H94) Oil heating/cooling The radiator of the power hydraulics, which is installed in the platform intermediate frame, has a cooling output of approx. 15 kW. If a higher cooling output is required, a radiator must be installed on the implement. Care must always be taken to ensure that the hydraulic components are matched to the respective usage case/operating point to avoid unnecessarily high power losses. When using flow rate controllers, the ma- ximum flow rate should never be exceeded.

47 Introduction of the New Unimog Generation | Model Series 405 – This printout will not be recorded by the update service. Status: 03 / 2013 –