Fuel Shutoff Valve C Series Page 5-38 Section 5 - Fuel System - Group 05 Install NOTE: Make sure the acorn nut is tightened to be snugly on the fuel shutoff solenoid shaft (Synchro-start only ). Install the new fuel shutoff solenoid to the bracket, and connect the wires. Make sure the wiring harness one the Trombetta solenoid is installed in the six-o'clock position. Torque Value: 10 N•m [ 89 in-lb ] 1. Synchro-start 2. Trombetta 3. Direct link. Activate the switch and check the plunger travel.
Synchro- start Trombetta Direct link 91.4 mm [3.6 in] B = 60.2 mm [2.4 in] A = 86.8 mm [3.4 in] 63.5 mm [2.5 in] 117.1 mm [4.61 in] The plunger must be retracted when the fuel shutoff solenoid is activated to the RUN position B. The fuel shutoff solenoid must operate without binding. Remove the hitch pin clip, the mounting capscrews, and the fuel shutoff solenoid. Install the new solenoid in reverse order of removal, and connect the wires. Torque Value: 10 N•m [ 89 in-lb ] Adjust the solenoid linkage as necessary so that the plunger is magnetically held in with the shutoff lever in the absolute full-run position.
Turn the large hex nut on the end of the plunger to make adjustments, and secure in place with a locknut.