Cummins — 3666003

Water Pump C Series Page 8-56 Section 8 - Cooling System - Group 08 Fill During filling, air must be vented from the engine coolant passages. Open the engine vent petcock if equipped. Also, be sure to open the petcock on the aftercooler for aftercooled engines. NOTE: Venting will permit a fill rate of 19 liters/min. [5 gal/ min.]. Close the drain valves. Install all hoses previously removed. Fill the cooling system with a premixture of 50-percent water and 50-percent ethylene-glycol antifreeze; refer to Procedure 008-018. NOTE:

The ability of antifreeze to remove heat from the engine is not as good as water; pouring antifreeze into the engine first can contribute to an overheated condition before the liquids are completely mixed. Operate the engine until it reaches a temperature of 80°C [176°F], and inspect for coolant leaks. Install the pressure cap.