Cummins — 3666003

C Series Exhaust Restriction Section 11 - Exhaust System - Group 11 Page 11-5 Marine Applications Connect a manometer to the turbocharger exhaust connection. Use a minumum of 305 mm [12 in] of metal tubing extending from the exhaust connection to protect the hose from heat. Operate the engine at rated rpm and load. Record the reading on the manometer. Exhaust Restriction Hg mm in 75 MAX 3 Exhaust Restriction H 2 0 mm in 1016 MAX 40 If exhaust restriction exceeds specifications, inspect the exhaust system for damage. Refer to the original equipment manufacturer (OEM) repair instructions. Remove manometer from the turbocharger exhaust connection.