I000893 Fig. 23. I000532 Fig. 24. I003578 Fig. 25. I003599 Fig. 26. 919 .. 0101-1000 925 .. 1001- 934 .. 0101-1000 919 .. 1001- 928 .. 0101-1000 934 .. 1001- 922 .. 0101-1000 928 .. 1001- 922 .. 1001- 931 .. 0101-1000 925 .. 0101-1000 931 .. 1001- Set quick lift switch to "Raise". The lifting gear rises up and remains in its uppermost position Set quick lift switch to "Lower". The linkage lowers and re- mains in its lowermost position If calibration is completed without errors, O.K. appears and the new sensor settings are saved. N OTE : Settings are only transferred when the ignition key has been turned to "0" position.
(Wait for at least 15 seconds before switching on the ig- nition again!) If faulty values are found, is displayed ERROR Place ignition key in position "0" Wait for at least 15 seconds before switching on ignition again! Carry out calibration again. Press "Return" to confirm Press "Return" to confirm 0000 - Overall system/tractor F - Setting and calibrating 238 T000336 Version 3 21-04-2009 F - Setting and calibrating