Fendt 900 Vario COM III — 1 Transmission control system functional sequence

1005 - Overall system/transmission A - General Hydrostatic power distribution The ML transmission unit is flexibly mounted in the transmission housing. The transmission housing is also the oil reser- voir for the hydrostatic drive. Oil fill: Fendt Extra Trans 10W-40 or STOU oil, viscosity SAE 10W-40 or 15W-40 Initial fill: approx. 87 l Refill: approx. 67 l, e.g. at oil change Functional sequence, see transmission hydraulic circuit diagram The servo pump draws in oil through the suction filter. The temperature sensor (B009) monitors the temperature of the transmission oil. Flow through the oil cooler is temperature-dependent.

This means that if the transmission oil is cold, little oil flows through the oil cooler, while most flows through the bypass valve. The bypass valve opens when the differential pressure exceeds approx. 3,5 bar. The transmission oil temperature is monitored by the temperature sensor. The servo pump generates the system pressure for the ML control valves and enhanced control valves. The system pres- sure of approx. 25 bar is restricted by the pressure-limiting valve and restrictor orifice. Pressure filter contamination is monitored by a pressure switch (S017) as a function of the transmission oil temperature.

Filter contamination is not monitored if the transmission oil temperature is below 50°. Two non-return valves (2V1 and 2V2) alternately feed cooled transmission oil into the high-pressure circuit. Hot transmission oil is discharged from the high-pressure circuit via the purge valve (2V5). The high-pressure circuit incorporates: a variable-displacement pump (2P1), two variable-displacement motors (2A1), two non-return valves (2V1 and 2V2), two servo-assisted high-pressure limiting valves (2V3 and 2V4), a purge valve (2V5), a clutch pressure-limiting valve (4V4), a turbo-clutch pressure-limiting valve (4V5) and a test connection (PH).

The variable-displacement cylinders (3A1 and 3A2) on the variable-displacement pump and motor are actuated by two 4/3-directional control valves (3V1 and 3V2). The 4/3 directional control valves are mechanically actuated by the actuator shaft (3Z1). The actuator shaft (3Z1) is rotated as required by the actuator unit (A009), thereby setting the correct quantity of oil to be supplied or consumed. The variable-displacement pump (2P1) and the two variable-displacement motors (2A1) swivel correspondingly. In the emergency mode switch position, the actuator shaft (3Z1) is actuated manually from the cab.

see §2 In the emergency mode switch position, the transmission is automatically locked at approx. 30 km/h after the engine has been started. If the clutch pedal, hand brake or neutral switch is operated, the high-pressure circuit is depressurised by the two high- pressure limiting valves (2V3 and 2V4). The clutch function is controlled by pressure-limiting valve (4V4), the turbo-clutch function by pressure-limiting valve (4V5). Important note on filling the ML 260 transmission with oil: During normal maintenance work, e.g. for a transmission oil change, the transmission oil should be added as in a normal change-gear transmission.

If there is no oil in the high-pressure circuit, the transmission must be filled from an external pressurised filling unit. During filling, the transmission oil is additionally filtered through connection PU (measuring point M5). If the oil pressure filling is not performed, the variable-displacement pump (2P1) and variable-displacement mo- tor (2A1) may become damaged as a result of dry running. Electrical/electronic control 7 T000458 Version 4 04-02-2010 The system uses three different pressures. 1. System pressure for ML transmission control, approx. 25 bar 2. Enhanced control pressure for the rear PTO clutch, rear PTO shaft control, differential lock and 4WD switchover.

En- hanced control pressure approx. 18 bar 3. High pressure in ML transmission max. 550 bar + 15 bar ML 260 transmission The ML 260 is a continuously variable transmission for forward and reverse travel. Power transmission can be hydrostatic or mechanical, or hydrostatic and mechanical. Basically this means:

Slow forward travel = high hydrostatic transmission power/low mechanical transmission power Fast forward travel = low hydrostatic transmission power/high mechanical transmission power For a detailed explanation, see transmission function plan 1 Transmission control system functional sequence Transmission type ML 260 M – Marschall, designer of this development L – Power distribution, mechanical and hydrostatic power transmission 260 – Vario transmission size 919 .. 0101-1000 925 .. 1001- 934 .. 0101-1000 919 .. 1001- 928 .. 0101-1000 934 .. 1001- 922 .. 0101-1000 928 .. 1001- 922 .. 1001- 931 .. 0101-1000 925 .. 0101-1000 931 .. 1001- A - General