MH MH6.6/MH8.6 — GB COPERTINA.fm

MH6.6 / MH8.6 MACHINE STRUCTURE 2-19 Switches / Keys (Fig. 7) Page 7 of 7 Carefully read personal and machine SAFETY INSTRUCTIONS (at the beginning of this manual) No. Designation Function Symbol 44 Key Hazard warning system Hazard warning system on/off T34 Buzzer Individual acoustic warning signals when:

- the self-test routine of the electronic control is in progress after "Ignition ON" - the return-flow filters of the hydraulic system are contaminated - the machine is switched over from stick func- tion to levelling blade / stabilizer function - during hydraulic hammer or cutter operation the machine has been switched over by means of pedal (77) temporarily to neck cylinder for repositioning movements - faults in the electronic control unit have oc- curred that do not constitute a severe threat to the safety of the operator and of the machine Further short acoustic warning signals:

- triple tone in the event of operating errors - double tone on switching over to forward travel - single tone on switching over to reverse travel - prolonged single tone when travel direction is shifted to neutral - single tone when key (33, Fig. 7) is pressed while the parking or the service brake is ap- plied Periodic acoustic warning signals when:

- the brake pressure too low - the engine oil pressure insufficient - the coolant temperature too high - the admissible load moment is exceeded (with overload warning option) - no voltage is supplied by the alternator - the temperature of the hydraulic oil too high - the "Stabilizers / levelling blade" raising and lowering function is on - severe faults have occurred in the electronic control module - emergency operation has been activated