MH6.6 / MH8.6 MACHINE STRUCTURE 2-33 Multifunction display (Fig. 5) Page 5 of 5 Carefully read personal and machine SAFETY INSTRUCTIONS (at the beginning of this manual) No. Designation Function Symbol 113 Warning lamp Fault message Lights up red, when the safety of persons (e.g. safety lever defec- tive, overload warning) and the functioning of main assemblies of the machine is endangered. This is the case, for instance, when there is no engine oil pres- sure or when the admissible load moment is being exceeded (with overload warning option) and when pressure-relief valves open.
When a red fault occurs, a fault number is displayed and an in- termittent buzzer warning is sounded in addition to the red warning lamp lighting up. In some fault cases, certain ma- chine functions are deactivated or can be switched over to emer- gency operation. There is also the possibility of several faults being indicated at the same time. If 2 red faults occur, both are indicated. If a yellow and red fault occur at the same time, only the red fault will be indicated. After removal of the cause of the red fault, the yellow fault is indicated. (See: "Fault codes")