MH6.6 / MH8.6 ELECTRONICS 4-9 Power supply and CAN bus in acc. with diagram P/N 8900299, sheet 37 Grounding Description The battery voltage +30 is available at the ignition starter switch S1 and the two diagnosis sockets. After switching on of the ignition with S1 and as long as the key is held in this position, battery volt- age +30 is connected to terminal +15 and: - the central electronic unit A100, also called Cen- tral Unit (CU), is supplied with power; - power relais K10.1 is energized; its contact en- ergizes relay K100 whereby the CU/A100 is sup- plied with power and starts booting; Fig. 2 - the ESX is supplied via the 30A fuse.
The ESX is moreover supplied with power via the 2A fuse; - relay K-ESX is energized. After booting of the CU, voltage Ub (15b) is avail- able at two contacts. - via X3A: 8 the modules display C4, keyboard modules C5.1, C5.2, C5.3, both joysticks and the travel pedal are supplied. The travel pedal as a master module supplies power to the double pedal (slave). - via X7:5-6 power relay K10.1 is energized for self-maintaining contact (after releasing of the ignition key); moreover load-limit regulator A10 is supplied with power. Fig. 3 All modules are connected to the central grounding point X31P on the platform plate. This grounding point penetrates through the plat- form plate.
Grounding point X31P of the elastically supported platform plate is connected with an earthing strap to the superstructure frame. The ESX is grounded via its fastening screws. Carefully read personal and machine SAFETY INSTRUCTIONS (at the beginning of this manual)