MH MH6.6/MH8.6 — GB COPERTINA.fm

ELECTRONICS MH6.6 / MH8.6 4-32 PCS in neutral PCS when working If no hydraulic function is activated, the power input of the main pumps is minimized by a high control current of the load limit regulator to the proportional valve Y10. When working with the working hydraulics, the speed signal of the diesel engine is evaluated, and the loading state of the engine is thus recog- nized, at each power stage. This means that any change in diesel engine speed to above or below the reference speed entails a control current adapted to the output of the diesel engine. The resulting control pressure is ca. 40 bars. The seven possible power stages would be no- ticeable only as engine speed stages.

This control current is the output signal of the load limit regulator. The proportional valve Y10 con- verts this control current proportionately into con- trol pressure pSt, causing the power regulator of the main pumps at connection X3 to be activated. During driving, only pump 1 is loaded. The me- chanical power setting of pump 1 complies closely with the installed diesel engine output. PCS when driving on the public highway Power stages 6 to 1 are given the engine speed and pump output of the next higher power stage. If the full hydraulic output is not utilized, the diesel engine speed rises to above the reference speed on account of the lower total load.

The result is that the load limit regulator counter-controls and increases the power intake of the main pumps by putting out a lower control current to the propor- tional valve in order to load the main pumps with a lower control pressure pSt. Power stage 7 is given a 5% higher pump output, which corresponds to the mechanical power set- ting of a pump. PCS when driving on terrain Power stages 7 to 1 are available for the driving function. The result is that the regulating pressure of the main pumps, which is within the normal range in this situation, is raised and the power input is in- creased by increasing the volumetric flow.

If further working functions are activated while the machine is being driven, the load limit of the die- sel engine is reached immediately, with the out- come that the control pressure pSt rises and the output of the main pumps is thus reduced. This power reduction continues until the power balance between the engine output and the hydraulic input is restored. If the main pumps are in the pressure range below the start of regulation, the load limit regulator sig- nal cannot influence the power input of the main pumps.

The electronic load limit regulation attained in this way in conjunction with individually output- controlled main pumps ensures optimum utiliza- tion of the available diesel engine output. Carefully read personal and machine SAFETY INSTRUCTIONS (at the beginning of this manual)