MH MH6.6/MH8.6 — GB COPERTINA.fm

ELECTRONICS MH6.6 / MH8.6 4-42 Proportional valve Y10 The emergency operation is properly adjusted if the machine can be used for working without con- siderable engine throttling. When the emergency operation function is activated, temperature monitoring is not operational. Technical characteristics, electrical: - PWM frequency: 150 Hz - Coil resistance at 20 °C: 18 Ω ± 0,2 Ω - Max. coil current: 850 mA Fig. 14 - Characteristics: 100 mA → 0 bar (+ 0.5 tolerance) 800 mA → 40.5 bar (+ 2.0/ -0.5 tolerance) Description The proportional valve converts the control current transmitted by load-limit regulator A10 into control pressure.

Characteristic curve of proportional valve Y10, control pressure as a function of control current: The control pressure is admitted via port X3 to both pump regulators of the main pumps A 8 V. Proportional valve Y10 is installed in the pilot con- trol unit where the pilot pressure is available at the control piston of the proportional valve. Emergency operation The proportional valve is equipped with an emer- gency operation device. In the event of a PCS fault and an resulting en- gine speed reduction, the absorbed power of the main pumps A 8 V can be reduced to such an extent that the diesel engine is no longer signifi- cantly throttled during the work.

Withdraw the connector from the proportional valve. Turn hex-screw in by abt. 2 turns after loosening the locknut. Let the engine run at maximum speed and load by moving the stick cylinder against block and by maintaining it there with an additional slewing motion of the superstructure of more than Ѕ turn. Observe the engine speed during the process: If the engine is still throttled, turn hex-screw fur- ther down. Fig. 15 If the engine maintains its speed under load and if the machine moves only slowly, the hex -screw has been turned into far. Carefully read personal and machine SAFETY INSTRUCTIONS (at the beginning of this manual)