MH6.6 / MH8.6 SAFETY INSTRUCTION 0-19 Prestressed units Safety instructions for accumulators Never open defective prestressed systems but replace the entire sys- tem. Accumulators are installed in the hydraulic system. They contain nitrogen under high initial pres- sure. Open only in exceptional cases, when the system and the opera- tional sequence are exactly known and the necessary special tools are available. Even when the hydraulic system has been depressurized, the nitro- gen pressure is maintained in the accumulator. The accumulators are completely safe in operation. If incorrectly han- dled, however, there is a risk of ex- plosion.
Never remove lead seals Never change the rated pressure of pressure-reducing valves without the explicit authorization of the manufacturer. The accumulators installed in this machine cannot be repaired. Defec- tive accumulators must be re- placed. Never handle accumulators me- chanically, never weld or solder them. Never remove lead seals from pressure-reducing valves and ac- cumulators. Before dismantling the accumula- tor, put on goggles and working gloves, and depressurize the hy- draulic system. Use original spares only. If in doubt, contact your local agent or the after-sales service.
Never remove or paint over warning and information plates, rating plates or type identification mark- ings. Replace illegible or damaged plates immediately. Carefully read personal and machine SAFETY INSTRUCTIONS (at the beginning of this manual)