MH6.6 / MH8.6 HYDRAULICS 5-31 Drive unit, variable displacement twin pump – output regulator (No. 3) The output regulator varies the pump discharge flow depending on the: - load-sensing pressure - pump pressure - load-limit regulator control pressure These three pressures act simultaneously on the output regulator and may therefore also be super- posed. The control pressure has priority and pre- vents the diesel engine from being overloaded by excessive power demands from the pumps. When the diesel engine is stationary, pumps 1 and 2 are adjusted by the spring (4) to maximum angle.
When the engine is running, the integrated pilot- control pump supplies oil to pump regulator port Y3 which acts via an internal channel on both out- put regulators. The pressure at port Y3 passes through shuttle valves past control piston (5) into control chamber A under control piston (8). Both pumps swivel to Vgmin. Carefully read personal and machine SAFETY INSTRUCTIONS (at the beginning of this manual)