MH MH6.6/MH8.6 — GB COPERTINA.fm

MH6.6 / MH8.6 HYDRAULICS 5-35 Description Example 1 The output regulator controls the pump discharge flow as a function of the pump high pressure in such a way that a predefined drive power is not exceeded. At a pressure of 140 bars, the regulator reduces the oil flow rate to 127 l/min. In this case, only adjusting spring (2) is engaged. The mechanical base power output adjustment for each regulator is performed with setscrew (19). This base power setting can be overridden by variable control pressures at port X3 depending on the power mode preselected.

With pump pressures below the power setting and a corresponding load-sensing signal at port X1, the pump is forced by the adjusting springs (2+3) to the Vgmax position. The pump works with maximum discharge flow for fast working movements. The rising pump pressure, e.g. in the event of excavating movements, acts on the measuring surface of the step piston (13) and thus via pin (12) and control piston (5) against power spring (17). When the hydraulic force exceeds the spring force, control piston (5) opens its control edge so that pump pressure passes into control chamber A below adjusting piston (8) which swivels the pump back.

The hydraulic force raises adjusting piston (8) at first against adjusting spring (2) and then, with pressure increasing further, additionally against adjusting spring (3). The pump adjusting process ends, when the forces of the adjusting springs and the hydraulic force under the adjust- ing piston are in equilibrium. The control piston (5) is raised again, closing the control edge in the process and thus the connection with adjusting piston surface A. The result is a discharge flow corresponding to the pump high pressure in ac- cordance with the spring characteristic in the out- put diagram.

A changing high pressure value re- sults in a new control cycle along the spring char- acteristic of the output diagram. This ensures that the drive power is not exceeded. Fig. 4 Example 2 At a pressure of 220 bars, the regulator reduces the oil flow rate to 77 l/min. In this case, both ad- justing springs (2+3) are engaged. Fig. 5 Carefully read personal and machine SAFETY INSTRUCTIONS (at the beginning of this manual)