MH MH6.6/MH8.6 — GB COPERTINA.fm

MH6.6 / MH8.6 HYDRAULICS 5-37 Description Example 3 The sum of the installed hydraulic power of all pumps exceeds the engine power installed. The electronic load-limit regulation now intervenes in the output regulation of the variable displacement twin pump in such a way that the discharge flow of the pumps is reduced until the total hydraulic power absorbed corresponds to the engine power supplied. With a pump pressure of 210 bars and a control pressure at X3 of 25.8 bars, the pump discharges a flow of 120 l/min.

For output regulation of the variable displacement twin pump, the pump regulators are fed with a con- trol pressure from the load-limit regulation which rises when the engine is overloaded and which drops when the engine loading diminishes. This variable control pressure acts through port X3 on both pump regulators. The step pistons (13) of both pump regulators receive pressure on the up- per measuring surface, where a downward hydrau- lic force is generated. This force is added to the hydraulic force existing due to the pump high pres- sure at the lower measuring surface of step piston (13).

Since the pressures of pump 1 and pump 2 are seldom at the same level during working, the ad- justing forces resulting at the output regulators lead to a different control behaviour. Fig. 7 The adjusting force resulting from the control pres- sure and the pump high pressure acts against the force of power spring (17). When the adjusting force prevails, control piston (5) is displaced downwards against the force of the adjusting springs (2+3) with its control edge opening towards control chamber A. The adjusting piston (8) changes the angle of the pump and thus its dis- charge flow until an equilibrium of forces is estab- lished in the output regulator.

Example 4 With a high pressure of 210 bars and a control pressure increase at X3 of 34 bars, the pump dis- charges only 80 l/min . The drive power for both pumps is thus adapted to the engine power even with different control ac- tions of the individual pumps. Fig. 8 Carefully read personal and machine SAFETY INSTRUCTIONS (at the beginning of this manual)