MH6.6 / MH8.6 HYDRAULICS 5-45 Description Oil flow from pump 2 In the description of the neutral circuit and of the other functions, the drive unit has been repre- sented in a simplified way. Pumps 1 and 2, the direct return to the filter and the return through the cooler (7) to filter (21) are only outlined. The follow- ing explanations refer to the neutral position of all control spools in the 6-spool control block. The oil flows through port P2 into the control block and then at first to pressure measuring point M2 and the primary pressure-limiting valve. Two parallel channels P2 and P02 direct the oil flow through the control block.
Channel P2 directs the oil flow to the relief valve, the pressure compensator and to the bucket pa- rallel circuit valve. Oil flow from pump 1 The oil flows through port P1 into the control block and then to pressure measuring point M1 and the primary valve for the pressure relief of pump 1. The relief valve and the pressure compensator are part of the adjusting spool circuit. They are controlled by the load pressure of the adjusting cylinder and ensure that a load-pressure- independent discharge flow supplies the adjusting cylinder. The excess oil from pump 2 that is not used by the adjusting cylinder is available via the relief valve to other functions.
The oil flows through the two parallel channels P1 and P01 to the control spools and the valves. Channel P1 directs the oil flow through a valve of the bucket parallel circuit to the bucket control spool. Channel P01 directs the oil flow to the travel spool with a branch-off ahead of the spool to a load- or pressure holding valve. The load-holding valve opens and the oil is available for further work at the travel spool. The oil flow by-passes the stabilizer spool and reaches the boom spool. A branch-off ahead of the spool directs the oil flow also via an- other load-holding valve to the boom spool.
The oil flows then to the bucket spool and is also available to the bucket spool via a load-holding valve. The oil passes then to the stick spool with a branch-off directing the oil also via a load-holding valve to the stick spool. The oil flow by-passes the adjusting spool (neck spool) and reaches the tank channel. The valve of the bucket parallel circuit opens and the oil flow from pump 2 joins the oil flow from pump 1. Both pumps supply partial oil volumes for the bucket parallel circuit. Channel P2 passes through the blanking plate (55) and continues as channel P02 through the control block.
In zero position of the adjusting spool, the oil flows to the stick spool with a branch-off ahead of the spool via a load-holding valve to the stick spool. The oil passes to the bucket spool with a load- holding valve opening the passage for the oil flow- ing to the bucket spool. The next spool to receive oil is the boom spool. This oil is also available via a load-holding valve to the boom function. The oil flows then to the stabilizer spool and is also available to this spool via another load-holding valve. The oil from pump 2 then flows past the travel spool into the tank channel. Carefully read personal and machine SAFETY INSTRUCTIONS (at the beginning of this manual)